nidaqmx.task.reference_trigger

class nidaqmx._task_modules.triggering.reference_trigger.ReferenceTrigger(task_handle, interpreter)[source]

Bases: object

Represents the reference trigger configurations for a DAQmx task.

property anlg_edge_coupling

Specifies the coupling for the source signal of the trigger if the source is a terminal rather than a virtual channel.

Type

nidaqmx.constants.Coupling

property anlg_edge_dig_fltr_enable

Specifies whether to apply a digital filter to the digital output of the analog triggering circuitry (the Analog Comparison Event). When enabled, the analog signal must stay above or below the trigger level for the minimum pulse width before being recognized. Use filtering for noisy trigger signals that transition in and out of the hysteresis window rapidly.

Type

bool

property anlg_edge_dig_fltr_min_pulse_width

Specifies in seconds the minimum pulse width thefilter recognizes.

Type

float

property anlg_edge_dig_fltr_timebase_rate

Specifies in hertz the rate of the digital filter timebase. NI-DAQmx uses this value to compute settings for the filter.

Type

float

property anlg_edge_dig_fltr_timebase_src

Specifies the terminal of the signal to use as the timebase of the digital filter.

Type

str

property anlg_edge_dig_sync_enable

Specifies whether to synchronize recognition of transitions in the signal to the internal timebase of the device.

Type

bool

property anlg_edge_hyst

Specifies a hysteresis level in the units of the measurement. If anlg_edge_slope is Slope1.RISING, the trigger does not deassert until the source signal passes below anlg_edge_lvl minus the hysteresis. If anlg_edge_slope is Slope1.FALLING, the trigger does not deassert until the source signal passes above anlg_edge_lvl plus the hysteresis. Hysteresis is always enabled. Set this property to a non-zero value to use hysteresis.

Type

float

property anlg_edge_lvl

Specifies in the units of the measurement the threshold at which the Reference Trigger occurs. Use anlg_edge_slope to specify on which slope to trigger at this threshold.

Type

float

property anlg_edge_slope

Specifies on which slope of the source signal the Reference Trigger occurs.

Type

nidaqmx.constants.Slope

property anlg_edge_src

Specifies the name of a virtual channel or terminal where there is an analog signal to use as the source of the Reference Trigger.

Type

str

property anlg_multi_edge_couplings

Specifies an list that describes the couplings for the corresponding source signal of the trigger if the source is a terminal rather than a virtual channel. Each element of the list corresponds to a source in Ref.AnlgMultiEdge.Srcs and an element in each of the other Analog Multi Edge property lists, if they are not empty.

Type

List[nidaqmx.constants.Coupling]

property anlg_multi_edge_hysts

Specifies an list of hysteresis levels in the units of the measurement or generation. If the corresponding element of Ref.AnlgMultiEdge.Slopes is Rising, the trigger does not deassert until the source signal passes below the corresponding element of Ref.AnlgMultiEdge.Lvls minus the hysteresis. If Ref.AnlgEdge.Slope is Falling, the trigger does not deassert until the source signal passes above Ref.AnlgEdge.Lvl plus the hysteresis. Hysteresis is always enabled. Set this property to a non-zero value to use hysteresis. Each element of the list corresponds to a source in Ref.AnlgMultiEdge.Srcs and an element in each of the other Analog Multi Edge property lists, if they are not empty.

Type

List[float]

property anlg_multi_edge_lvls

Specifies an list of thresholds in the units of the measurement or generation to start acquiring or generating samples. Each element of the list corresponds to a source in Ref.AnlgMultiEdge.Srcs and an element in each of the other Analog Multi Edge property lists, if they are not empty.

Type

List[float]

property anlg_multi_edge_slopes

Specifies an list of slopes on which to trigger task to start generating or acquiring samples. Each element of the list corresponds to a source in Ref.AnlgMultiEdge.Srcs and an element in each of the other Analog Multi Edge property lists, if they are not empty.

Type

List[nidaqmx.constants.Slope]

property anlg_multi_edge_srcs

Specifies a List and/or range of analog sources that are going to be used for Analog triggering. Each source corresponds to an element in each of the Analog Multi Edge property lists, if they are not empty.

Type

str

property anlg_win_btm

Specifies the lower limit of the window. Specify this value in the units of the measurement.

Type

float

property anlg_win_coupling

Specifies the coupling for the source signal of the trigger if the source is a terminal rather than a virtual channel.

Type

nidaqmx.constants.Coupling

property anlg_win_dig_fltr_enable

Specifies whether to apply a digital filter to the digital output of the analog triggering circuitry (the Analog Comparison Event). When enabled, the analog signal must stay within the trigger window for the minimum pulse width before being recognized. Use filtering for noisy trigger signals that transition in and out of the window rapidly.

Type

bool

property anlg_win_dig_fltr_min_pulse_width

Specifies in seconds the minimum pulse width the filter recognizes.

Type

float

property anlg_win_dig_fltr_timebase_rate

Specifies in hertz the rate of the digital filter timebase. NI-DAQmx uses this value to compute settings for the filter.

Type

float

property anlg_win_dig_fltr_timebase_src

Specifies the terminal of the signal to use as the timebase of the digital filter.

Type

str

property anlg_win_dig_sync_enable

Specifies whether to synchronize recognition of transitions in the signal to the internal timebase of the device.

Type

bool

property anlg_win_src

Specifies the name of a virtual channel or terminal where there is an analog signal to use as the source of the Reference Trigger.

Type

str

property anlg_win_top

Specifies the upper limit of the window. Specify this value in the units of the measurement.

Type

float

property anlg_win_trig_when

Specifies whether the Reference Trigger occurs when the source signal enters the window or when it leaves the window. Use anlg_win_btm and anlg_win_top to specify the window.

Type

nidaqmx.constants.WindowTriggerCondition1

property auto_trig_enable

Specifies whether to send a software trigger to the device when a hardware trigger is no longer active in order to prevent a timeout.

Type

bool

property auto_triggered

Indicates whether a completed acquisition was triggered by the auto trigger. If an acquisition has not completed after the task starts, this property returns False. This property is only applicable when auto_trig_enable is True.

Type

bool

cfg_anlg_edge_ref_trig(trigger_source, pretrigger_samples, trigger_slope=Slope.RISING, trigger_level=0.0)[source]

Configures the task to stop the acquisition when the device acquires all pretrigger samples; an analog signal reaches the level you specify; and the device acquires all post-trigger samples. When you use a Reference Trigger, the default for the read RelativeTo property is first_pretrigger_sample with a read Offset of 0.

Parameters
  • trigger_source (str) – Is the name of a virtual channel or terminal where there is an analog signal to use as the source of the trigger.

  • pretrigger_samples (int) – Specifies the minimum number of samples to acquire per channel before recognizing the Reference Trigger. The number of post-trigger samples per channel is equal to number of samples per channel in the DAQmx Timing function minus pretrigger_samples.

  • trigger_slope (Optional[nidaqmx.constants.Slope]) – Specifies on which slope of the signal the Reference Trigger occurs.

  • trigger_level (Optional[float]) – Specifies at what threshold to trigger. Specify this value in the units of the measurement or generation. Use trigger_slope to specify on which slope to trigger at this threshold.

cfg_anlg_window_ref_trig(trigger_source, window_top, window_bottom, pretrigger_samples, trigger_when=WindowTriggerCondition1.ENTERING_WINDOW)[source]

Configures the task to stop the acquisition when the device acquires all pretrigger samples; an analog signal enters or leaves a range you specify; and the device acquires all post- trigger samples. When you use a Reference Trigger, the default for the read RelativeTo property is first_pretrigger_sample with a read Offset of 0.

Parameters
  • trigger_source (str) – Is the name of a virtual channel or terminal where there is an analog signal to use as the source of the trigger.

  • window_top (float) – Is the upper limit of the window. Specify this value in the units of the measurement or generation.

  • window_bottom (float) – Is the lower limit of the window. Specify this value in the units of the measurement or generation.

  • pretrigger_samples (int) – Specifies the minimum number of samples to acquire per channel before recognizing the Reference Trigger. The number of post-trigger samples per channel is equal to number of samples per channel in the DAQmx Timing function minus pretrigger_samples.

  • trigger_when (Optional[nidaqmx.constants.WindowTriggerCondition1]) – Specifies whether the Reference Trigger occurs when the signal enters the window or when it leaves the window. Use window_bottom and window_top to specify the limits of the window.

cfg_dig_edge_ref_trig(trigger_source, pretrigger_samples, trigger_edge=Edge.RISING)[source]

Configures the task to stop the acquisition when the device acquires all pretrigger samples, detects a rising or falling edge of a digital signal, and acquires all posttrigger samples. When you use a Reference Trigger, the default for the read RelativeTo property is first_pretrigger_sample with a read Offset of 0.

Parameters
  • trigger_source (str) – Specifies the name of a terminal where there is a digital signal to use as the source of the trigger.

  • pretrigger_samples (int) – Specifies the minimum number of samples to acquire per channel before recognizing the Reference Trigger. The number of post-trigger samples per channel is equal to number of samples per channel in the DAQmx Timing function minus pretrigger_samples.

  • trigger_edge (Optional[nidaqmx.constants.Edge]) – Specifies on which edge of the digital signal the Reference Trigger occurs.

cfg_dig_pattern_ref_trig(trigger_source, trigger_pattern, pretrigger_samples, trigger_when=DigitalPatternCondition.PATTERN_MATCHES)[source]

Configures the task to stop the acquisition when the device acquires all pretrigger samples, matches a digital pattern, and acquires all posttrigger samples. When you use a Reference Trigger, the default for the read RelativeTo property is First PretriggerSample with a read Offset of zero.

Parameters
  • trigger_source (str) – Specifies the physical channels to use for pattern matching. The order of the physical channels determines the order of the pattern. If a port is included, the order of the physical channels within the port is in ascending order.

  • trigger_pattern (str) – Specifies the digital pattern that must be met for the trigger to occur.

  • pretrigger_samples (int) – Specifies the minimum number of samples to acquire per channel before recognizing the Reference Trigger. The number of post-trigger samples per channel is equal to number of samples per channel in the DAQmx Timing function minus pretrigger_samples.

  • trigger_when (Optional[nidaqmx.constants.DigitalPatternCondition]) – Specifies the condition under which the trigger occurs.

property delay

Specifies in seconds the time to wait after the device receives the Reference Trigger before switching from pretrigger to posttrigger samples.

Type

float

property dig_edge_dig_fltr_enable

Specifies whether to apply a digital filter to the trigger signal.

Type

bool

property dig_edge_dig_fltr_min_pulse_width

Specifies in seconds the minimum pulse width the filter recognizes.

Type

float

property dig_edge_dig_fltr_timebase_rate

Specifies in hertz the rate of the digital filter timebase. NI-DAQmx uses this value to compute settings for the filter.

Type

float

property dig_edge_dig_fltr_timebase_src

Specifies the terminal of the signal to use as the timebase of the digital filter.

Type

str

property dig_edge_dig_sync_enable

Specifies whether to synchronize recognition of transitions in the signal to the internal timebase of the device.

Type

bool

property dig_edge_edge

Specifies on what edge of a digital pulse the Reference Trigger occurs.

Type

nidaqmx.constants.Edge

property dig_edge_src

Specifies the name of a terminal where there is a digital signal to use as the source of the Reference Trigger.

Type

str

property dig_pattern_pattern

Specifies the digital pattern that must be met for the Reference Trigger to occur.

Type

str

property dig_pattern_src

nidaqmx.system.physical_channel.PhysicalChannel: Specifies the physical channels to use for pattern matching. The order of the physical channels determines the order of the pattern. If a port is included, the order of the physical channels within the port is in ascending order.

property dig_pattern_trig_when

Specifies whether the Reference Trigger occurs when the physical channels specified with dig_pattern_src match or differ from the digital pattern specified with dig_pattern_pattern.

Type

nidaqmx.constants.DigitalPatternCondition

disable_ref_trig()[source]

Disables reference triggering for the measurement.

property max_num_trigs_to_detect

Specifies the maximum number of times the task will detect a reference trigger during the task. The number of times a trigger is detected and acted upon by the module may be less than the specified amount if the task stops early because of trigger/retrigger window expiration. Specifying the Maximum Number of Triggers to Detect to be 0 causes the driver to automatically set this value to the maximum possible number of triggers detectable by the device and configuration combination. Note: The number of detected triggers may be less than number of trigger events occurring, because the devices were unable to respond to the trigger.

Type

int

property pretrig_samples

Specifies the minimum number of pretrigger samples to acquire from each channel before recognizing the reference trigger. Post-trigger samples per channel are equal to samp_quant_samp_per_chan minus the number of pretrigger samples per channel.

Type

int

property retrigger_win

Specifies the duration in seconds after each trigger during which the device may trigger. Once the window has passed, the device stops detecting triggers, and the task will stop after the device finishes acquiring post-trigger samples that it already started. Specifying a Retrigger Window of -1 causes the window to be infinite.

Type

float

property retriggerable

Specifies whether a finite task resets, acquires pretrigger samples, and waits for another Reference Trigger after the task completes. When you set this property to True, the device will acquire post-trigger samples, reset, and acquire pretrigger samples each time the Reference Trigger occurs until the task stops. The device ignores a trigger if it is in the process of acquiring signals.

Type

bool

property term

Indicates the name of the internal Reference Trigger terminal for the task. This property does not return the name of the trigger source terminal.

Type

str

property timestamp_enable

Specifies whether the reference trigger timestamp is enabled. If the timestamp is enabled but no resources are available, an error will be returned at run time.

Type

bool

property timestamp_timescale

Specifies the reference trigger timestamp timescale.

Type

nidaqmx.constants.Timescale

property trig_type

Specifies the type of trigger to use to mark a reference point for the measurement.

Type

nidaqmx.constants.TriggerType

property trig_win

Specifies the duration in seconds after the task starts during which the device may trigger. Once the window has passed, the device stops detecting triggers, and the task will stop after the device finishes acquiring post-trigger samples that it already started. If no triggers are detected during the entire period, then no data will be returned. Specifying a Trigger Window of -1 causes the window to be infinite.

Type

float